Analysis on the problems of dust filter fans

In the case of small dust volume treatment, the aerodynamic effect provided by the fan is small due to the small amount of air treatment, and the inertial force of the fiber in the direction of motion of the airflow is less than that of inertial force. As a function, most of the dust will be s ---MORE---

Posted on

Briefly consider the considerations of air supply in ai…

Air supply for air conditioning purification system (1) In the air conditioning system, in addition to the integrated unit, there is generally a refrigeration station, a heat exchange station, a boiler room, and a pump house. This requires normal operation of each power facility and interlo ---MORE---

Posted on

Design of remote monitoring software for offshore wind …

The remote monitoring software design of the offshore wind turbine control system is designed and developed in the NET Framework environment. The BS architecture mode is adopted, and the SQL Server database is used for data storage management. The software runs on the central controller. The m ---MORE---

Posted on

Wind power transmission systems, especially for offshor…

During the seabed paving, the wind farm and the outgoing cable are placed on the seabed by the laying ship, and the seabed is impacted by high-pressure water jet, and then the cable is buried 1m deep under the seabed. If the surface of the sea floor is hard rock, a stone or gravel layer can be ---MORE---

Posted on

Realize the start and stop operation of the blower and …

In order to ensure the safe operation of the inverter, the inverter sends out a fault alarm signal and a fault shutdown signal according to its own operating conditions. When the fault stop signal occurs, the protection system should be able to cut off the QF within 80ms. In addition, in order ---MORE---

Posted on

Factors affecting the efficiency of the ventilator

The self-tight rotary vane damper is a quick opening and closing and sectional adjustable damper specially developed for realizing non-stop wind down. The self-sealing rotary vane damper is used as the regulating damper of the main fan. It has the characteristics of high automation, fast switc ---MORE---

Posted on

Bottom heating of circulating fluidized bed boiler

When the circulating fluidized bed boiler is started in the preheating and cold state, the temperature of the boiler water is generally controlled at about 70 °C. The water temperature of the boiler steam drum is about 35 °C due to the heat dissipation of the heating surface. Some change ---MORE---